Profiling an IR Reflow Oven After Maintenance or Lamp Changes

August 20, 2026

Profiling an IR Reflow Oven After Maintenance or Lamp Changes

Profiling an IR Reflow Oven After Maintenance or Lamp Changes

Work on a lamp, reflector, guard or window, fan, sensor or controller can change the delivered heat field. Use a series of release gates; a successful startup is only the first observation.

  1. Verify the change record, installed part, drawing and orientation.
  2. Check current, spacing, cooling, guards and interlocks.
  3. Run the established instrumented board from its defined start state.
  4. Compare hot/cold ramp, time bands, peak, cooling, zone outputs and repeatability.
  5. Confirm solder or process results before release. Investigate unexplained controller compensation. A controller may hold one sensor at its setpoint while driving a weak zone harder. Preserve the records from before and after maintenance, and link the approved lamp revision to the spare-parts inventory. Identify every Goldisgood replacement selected from the documented range by its exact voltage, power, active length, terminal configuration and optical revision. Related: optical contamination and hot/cold locations.